Project

General

Profile

Manufacturing Process » History » Version 3

Dimitris Pipelias, 11/18/2025 10:47 AM

1 1 Dimitris Pipelias
# Manufacturing Process
2
#
3
#
4
#
5
6
### 1. PCB Manufacturing / Soldering
7
8
Description of the printed circuit board (PCB) manufacturing and soldering process.
9
1. PCB preparation
10
2. Component placement
11
3. Soldering process
12
4. Visual inspection
13
๐Ÿ“Œ Note: Insert photos here showing the PCB manufacturing steps.
14
#
15
16
### 2. Components Assembly
17
Description of the procedure for assembling the electronic components of the amplifier.
18
1. Module placement
19
2. Wiring
20
3. Securing components
21
4. Functional testing
22
๐Ÿ“Œ Note: Insert images here showing assembly steps.
23
#
24
25
### 3. Testing / Case Assembly
26
27 3 Dimitris Pipelias
![](image1.jpg)
28 1 Dimitris Pipelias
29
1. Visual inspection to ensure that all components on the board are correctly placed.
30
2. Check for a missing coil, as this is a common failure point (Fig. 1).
31
3. Set the HDMOD-1 source to an RF output of 90dB on channel 21 (MHz: fill in the exact frequency).
32
4. Connect the output to a 20dB attenuator.
33
5. Measure the PWR level at the output of the 20dB attenuator using the field meter. The desired power value to confirm correct operation of the source before connecting the amplifier is 69dB (Fig. 2).
34
 ๐Ÿ“Œ Note: 90dB (source) โ€“ 20dB (attenuator) + 36dB (DA102 amplifier) โ€“ 1dB (cable losses) = 69dB.
35
6. Place the amplifier between the source and the field meter, and power it with 12V DC, verifying a current consumption of approximately 270mA (Fig. 3).
36
7. Set the attenuation and equalizer switches to their maximum position (Fig. 4).
37
8. Connect the output to a 30dB attenuator (required due to the DA102 36dB gain).
38
9. Measure the PWR level at the output of the 30dB attenuator using the field meter. The desired power value to confirm correct operation of the DA102 amplifier is 75dB (Fig. 5).
39
 ๐Ÿ“Œ Note: 90dB (source) โ€“ 20dB (first attenuator) + 36dB (DA102 amplifier) โ€“ 30dB (second attenuator) โ€“ 1dB (cable losses) = 75dB.
40
#
41
42
### Step-by-Step Workflow
43
1. Materials and PCB reception
44
2. Incoming quality control
45
3. Soldering and visual inspection
46
4. Components assembly
47
5. Wiring
48
6. Housing installation
49
7. Final functional testing
50
8. Packaging
51